BZHGL - 11-4264 DIAMOND/CUBIC BORON NITRIDE GRINDING WHEELS
- MSDS: BZHGL
- Manufacturer: BUEHLER LTD
- Product Name: 11-4264 DIAMOND/CUBIC BORON NITRIDE GRINDING WHEELS
- National Stock Number: 6850-00F048733
Product Identification
Product ID:11-4264 DIAMOND/CUBIC BORON NITRIDE GRINDING WHEELS
MSDS Date:08/29/1995
FSC:6850
NIIN:00F048733
MSDS Number: BZHGL
Responsible Party
LAKE BLUFF, IL 60044-1687
US
Emergency Phone: 708-295-6500
Info Phone: 708-295-6500
Cage: 09410
Contractor
Telephone: 847-295-8500
Cage: 09410
Ingredients
ALUMINUM OXIDE, BAUXITE, ALUMINA, DIALUMINUM TRIOXIDE
CAS: 1344-28-1
RTECS: BD1200000
Fraction By Weight: 81%
OSHA PEL 15 MG/CUM
ACGIH TLV: 10 MG/CUM
NICKEL (SUSPECTED ANIMAL/HUMAN CARCINOGEN BY IARC GROUP 2B,
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 82%
OSHA PEL 1 MG/CUM
ACGIH TLV: 0.05 MG/CUM IC
PHOSPHORUS (YELLOW & WHITE)
CAS: 7723-14-0
RTECS: TH3500000
Fraction By Weight: 1%
OSHA PEL 0.1 MG/CUM
ACGIH TLV: 0.1 MG/CUM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
MANGANESE, MN COMPOUNDS
CAS: 7439-96-5
RTECS: OO9275000
Fraction By Weight: 3%
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM (DUST)
MOLYBDENUM (SOLUBLE COMPOUND)
CAS: 7439-98-7
RTECS: QA4680000
Fraction By Weight: 1-10%
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
SILICON
CAS: 7440-21-3
RTECS: VW0400000
Fraction By Weight: 5%
ACGIH TLV: 10 MG/CUM
CRYSTALLINE-QUARTZ SILICA, SILICA DUST (SUSPECTED HUMAN
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: <1%
OSHA PEL 10 MG/CUM %RESP SIO2
ACGIH TLV: 0.1 MG/CUM RESP DUST
TUNGSTEN CARBIDE
CAS: 12070-12-1
RTECS: YO7250000
Fraction By Weight: 20%
ACGIH TLV: 5 MG(W)/M3
SILVER * 96-2 *
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: 85%
OSHA PEL 0.01 MG/CUM
ACGIH TLV: 0.1 MG/CUM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
COBALT (ANIMAL CARCINOGEN BY IARC - GROUP 2B) *96-2*
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 60%
OSHA PEL 0.1 MG/CUM
ACGIH TLV: 0.05 MG/CUM
COPPER (DUST & MIST), BRONZE POWDER *96-2*
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: 85%
OSHA PEL 0.1 MG(CU)/M3 (FUME)
ACGIH TLV: 0.2 MG/M3 (FUME)
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
TIN (AS SN)
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: 25%
OSHA PEL 2 MG/CUM
ACGIH TLV: 2.0 MG/CUM
GRAPHITE
CAS: 7782-42-5
RTECS: MD9659600
Fraction By Weight: 20%
ACGIH TLV: 2 MG/CUM RESP IC
SILICON CARBIDE
CAS: 409-21-2
RTECS: VW0450000
Fraction By Weight: 73%
ACGIH TLV: 10 MG/CUM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: CHRONIC-MAY AFFECT
BREATHING CAPACITY. SKIN/EYES: IRRITATION.
Explanation of Carcinogenicity:SEE INGREDIENTS
Effects of Overexposure:COUGH, IRRITATION.
Medical Cond Aggravated by Exposure:PRE-EXISTING RESPIRATORY
CONDITIONS.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED. SKIN:
WASH W/SOAP & WATER. EYES: WASH W/WATER. OBTAIN MEDICAL ATTENTION
IN ALL CASES.
Fire Fighting
Extinguishing Media:WATER
Fire Fighting Procedures:NONE
Accidental Release
Spill Release Procedures:NORMAL CLEANUP PROCEDURES.
Handling
Handling and Storage Precautions:HANDLE W/ADEQUATE VENTILATION.
Exposure Controls
Respiratory Protection:AS NEEDED FOR APPROVED DUST RESPIRATORS.
Ventilation:LOCAL EXHAUST, MECHANICAL: RECOMMENDED.
Protective Gloves:RECOMMENDED.
Eye Protection:RECOMMENDED.
Other Protective Equipment:AS NEEDED HEARING PROTECTION.
Supplemental Safety and Health
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:>428F
Spec Gravity:2-4
Solubility in Water:SLIGHT
Appearance and Odor:MAY GIVE OFF ODOR IN USE.
Stability
Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:IN USE DUST & DECOMPOSING ODORS ARE
GENERATED. COOLANTS MAY PRODUCE OTHER DECOMPOSITION PRODUCTS.
Disposal
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.